DIXION Respiratory Ventilator Aero 4500+

DIXION Respiratory Ventilator Aero 4500+

Aeros 4600 Plus combines the advantages of a flexible noninvasive ventilator with a full-featured invasive ventilator for the ICU.

Download Brosur

Features :Specification :Certificate :
  • 12.1″ TFT color touch screen
  • Comprehensive ICU ventilator including BIVENT and PRVC
  • Compact, big capacity battery, no air compressor, intra-hospital mobility
  • Flexible device configuration: equipped on a trolley, bed or ceiling pendant
  • Unique metal-based, autoclavable, heated exhalation valve
  • Built-in flow sensor, non-consumable design
  • Upgradeable ventilation system software, with an available USB port

Features

Description

Ventilation mode

 

VCV (A/C), PCV (A/C), PRVC (optional), PSV (optional), STANDBY SIMV (VCV)
+ PSV, SIMV (PCV)+PSV, SIMV (PRVC)+PSV SPONT/CPAP+PSV BIVENT/APRV + PSV
(optional) NIV/CPAP, NIV-T, NIV-S/T
Enhancements

 

Apnea ventilation, Pressure and Flow trigger, Automatic Tube Compensation
(ATC), Smart suction Manual breath, Insp/Exphold, Screen freeze,
Nebulization, Lung recruitment
Tidal volume (VT) ± 20-2000ml
Respiratory rate (RR) ± 1 to 80 bpm
Inspiratory time (Ti) ± 0.2 to 9 s (adult), 0.2 to 5 s (pediatric)
Inspiratory flow (Flow) ± 0 to 100 L/min (pediatric), 0 to 180L/min (adult)
Inspiratory pressure (Pinsp) ± 5 to 70 mbar (or cmH2O)
Inspiratory pressure limit (Pmax) ± 80 mbar (or cmH2O)
PEEP ± 0 to 35 mbar (or cmH2O)
Tslope ± 0 to 2 s
O2 concentration (FiO2) ± 21 to 100 Vol%
Trigger sensitivity ± 0.5 to 20 L/min (Flow trigger), -20 to 0 mbar (or cmH2O)
(Pressure trigger)
I/E ratio ± 1/10 to 4/1
Apnea alarm time ± 10-60 seconds
Monitoring

 

Pressure values Pplat, Ppeak,
Pmean, Pmin, PEEP

Volume/Flow values VTI,
VTE, MV, MVe, MVspont

Time values ftotal, fspont, I:E

Loops Pressure-Volume loop,
Pressure-Flow loop, Flow-Volume loop

Inspiratory O2 concentration
(FiO2), End-expiratory CO2 concentration (etCO2)

Compliance (dynamic &
static), Resistance (R), MVleak, RSBI, WOB, I:E, Vdaw, PEEPi

Alarm

 

Expiratory minute volume (MV) High/Low,

Airway pressure (Paw) High/Low,

VTe Low,

PEEP High/Low,

Insp. O2 concentration
(FiO2) High/Low,

End-expiratory CO2
concentration (etCO2) High/Low, fspont High,

Apnea alarm,

Disconnection,

Flow sensor error,

Gas supply,

Electrical supply & battery failure,

Exhalation obstruction,

Apnea backup for low frequency alarm

± = Tolerance Measurement 10%

CE
EN ISO 9001
EN ISO 13485

Leave a Reply