DIXION Patient Monitor Storm 5900

DIXION Patient Monitor Storm 5900

This monitor is portable and compact. It offers high-performance monitoring suitable for adults and children.

Parameters :

 

ECG

Respiration

NIBP

Temperature

SpO2

IBP

EtCO2

E-Catalogue

Storm 5900-01

 

 

  E-Catalogue

Storm 5900-02

 

  E-Catalogue

Storm 5900-04

 

  E-Catalogue

Storm 5900-05

  E-Catalogue

Download Brosur

Features :Specification :Certificate :
  • Displaying up to 11 curves simultaneously
  • 10.4″ antiglare TFT multimode display (800 x 600)
  • 5 – 7 Parameters (ECG, SpO2, Resp., NIBP, Temp., IBP, EtCO2)
  • Built-in Li-ion battery
  • Arrhythmia and S-T segment analysis
  • 3-level audible and visible alarm capability
  • Compatible with Dixion central monitoring system
  • High storage capacity : 96 hour graphic and tabular trends of all parameters
  • USB, Ethernet
  • Thermal printer (option)
  • VGA output, Wi-Fi (option)

Features

Description

ECG

3/5 leads

ECG curves

2 or 7 curves review

Gain selection

x0.125; x0.25; x0.5; x1, x2, x4; auto

Sweep speed

6.25; 12.5; 25; 50 mm/s

S-T segment analysis

Available

Arrhythmia analysis

Available

Heart rate

Measurement range : ± 15-300 bpm

Respiration

Impedance between RA-LL (R-F)

Measurement range

Adults                         : ± 0-120 bpm

Pediatric/neonatal       : ± 0-120 bpm

Apnea alarm

Available

Apnea delay

10-40 seconds

NIBP

Oscillometric

Manual/automatic/continuous

Measurement types

Systolic, diastolic, map

Measurement range

Adult        :      Sys    : ± 40-270 mmHg

                        Dia    : ± 10-215 mmHg

                        Map   : ± 20-235 mmHg

Pediatric   :      Sys    : ± 40-200 mmHg

                        Dia    : ± 10-150 mmHg

                        Map  : ± 20-165 mmHg

Neonatal   :     Sys    : ± 40-135 mmHg

                        Dia    : ± 10-100 mmHg

                        Map  : ± 20-110 mmHg

Temperature

Measurement range

± 0-50 °C

Channel

2-channel

SpO2

Measurement range : 0-100 %

Pulse Rate

Measuring and Alarm Range : 30-254 bpm

IBP

Measurement range

-50 – (+300) mmHg

Channel

2-channel

Pressure type

ART, PAP, CVP, RAP, LAP, ICP, P1, P2

Capnometry EtCO2

Infrared absorption technique

Measurement range

± 0-150 mmHg

Apnea alarm

Available

Calculation

lnsCO2, AwRR

Dimensions

320 x 150 x 265 mm

Weight

5 kg

± = Tolerance Measurement 10%

CE
EN ISO 9001
EN ISO 13485