Parameters :

 

ECG

Respiration

NIBP

Temperature

SpO2

IBP

Cardiac Output

EtCO2

E-Catalogue

Storm 5600-01

 

 

 

E-Catalogue

Storm 5600-02

 

 

E-Catalogue 

Storm 5600-03

 

E-Catalogue 

Storm 5600-04

 

 

E-Catalogue 

Storm 5600-05

 

E-Catalogue 

Storm 5600-06

(Option)

Download Brosur

Features :Specification :Certificate :
    • 15” TFT LCD display, touch screen (option)
    • Displaying up to 13 curves simultaneously
    • 5 – 8 Parameters (ECG, SpO2, Resp., NIBP, Temp., IBP, Cardiac Output, EtCO2)
    • Displaying and analyzing of 12 ECG leads (option)
    • Storing graphical and tabular trends of all parameters of the last 120 hours, 1200 NIBP measurement results and 60 alarm events
    • Nurse call function, Bed to bed view
    • Output : VGA, USB (at least one), Lan, Wi-Fi (option), and Defibrillator synchronization
    • Built-in rechargeable Li-ion battery
    • Compatible with Dixion central monitoring system
  • Suitable for adult, pediatric and neonatal patients

Features

Description

ECG

3/5 leads, 12 (option)

ECG curves

2 or 7 curves review

Gain selection

x0.125; x0.25; x0.5; x1, x2; auto

Sweep speed

6.25; 12.5; 25; 50 mm/s

S-T segment analysis

Available

Arrhythmia analysis

Available

Heart rate

Measurement range : ± 15-300 bpm

Respiration

Impedance between RA-LL (R-F)

Measurement range

Adults                     : ± 6-120 bpm

Pediatric/neonatal   : ± 6-150 bpm

Apnea alarm

Available

Apnea delay

10-40 seconds

NIBP

Oscillometric

Manual/automatic/continuous

Measurement types

Systolic, diastolic, map

Measurement range

Adult        :    Sys    : ± 40-270 mmHg

                      Dia    : ± 10-215 mmHg

                      Map   : ± 20-235 mmHg

Pediatric   :    Sys    : ± 40-230 mmHg

                      Dia    : ± 10-180 mmHg

                      Map   : ± 20-195 mmHg

Neonatal   :   Sys     : ± 40-135 mmHg

                      Dia    : ± 10-100 mmHg

                      Map   : ± 20-110 mmHg

Temperature

Measurement range

± 0-50°C

Channel

2-channel

SpO2

Measurement range : ± 20-100 %

Pulse Rate

Measuring and Alarm Range : ± 30-254 bpm

Cardiac output

Thermodilution

IBP

Measurement range

-50 – (+300) mmHg

Channel

2-channel

Pressure type

ART, PAP, CVP, RAP, LAP, ICP, P1, P2

Capnometry EtCO2

Infrared absorption technique

Measurement range

± 0-150 mmHg

Apnea alarm

available

Calculation

lnsCO2, AwRR

Dimensions

370 x 175 x 320 mm

Weight

7 kg

± = Tolerance Measurement 10%